ABB A210-30-22 220-230V 50Hz / 230-240V 60Hz Contactor, P/N : 1SFL511001R8022

SKU: 1SFL511001R8022 Category:

Extended Product Type: A210-30-22 220-230V 50Hz / 230-240V 60Hz

Product ID: 1SFL511001R8022

EAN: 7320500212899

Catalog Description: A210-30-22 220-230V 50Hz / 230-240V 60Hz Contactor

Long Description: A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 690 V.Operated with control voltage, versions from 24….690 AC, 50 and 60 Hz

TECHNICAL:

  • Number of Main Contacts NC:
    0
  • Number of Auxiliary Contacts NO:
    2
  • Number of Auxiliary Contacts NC:
    2
  • Rated Operational Voltage:
    Main Circuit 690 V
  • Rated Frequency (f):
    Main Circuit 50/60 Hz
  • Conventional Free-air Thermal Current (Ith):
    acc. to IEC 60947-4-1, Open Contactors q = 40 °C 350 A
  • Rated Operational Current AC-1 (Ie):
    (690 V) 55 °C 300 A
    (690 V) 40 °C 350 A
    (690 V) 70 °C 240 A
  • Rated Operational Current AC-3 (Ie):
    (690 V) 55 °C 210 A
    (415 V) 55 °C 210 A
    (220 / 230 / 240 V) 55 °C 210 A
    (440 V) 55 °C 210 A
    (380 / 400 V) 55 °C 210 A
    (500 V) 55 °C 210 A
  • Rated Operational Power AC-3 (Pe):
    (500 V) 132 kW
    (690 V) 160 kW
    (220 / 230 / 240 V) 59 kW
    (380 / 400 V) 110 kW
    (440 V) 110 kW
    (415 V) 110 kW
  • Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1:
    8 x Ie AC-3
  • Rated Making Capacity AC-3 acc. to IEC 60947-4-1:
    10 x Ie AC-3
  • Short-Circuit Protective Devices:
    gG Type Fuses 400 A
  • Rated Short-time Withstand Current (Icw):
    at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 400 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1200 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1700 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 2500 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1000 A
  • Maximum Breaking Capacity:
    cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 2200 A
    cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 2000 A
  • Maximum Electrical Switching Frequency:
    AC-3 300 cycles per hour
    AC-1 300 cycles per hour
    AC-2 / AC-4 150 cycles per hour
  • Rated Operational Current DC-1 (Ie):
    (110 V) 2 Poles in Series, 40 °C 350 A
    (220 V) 3 Poles in Series, 40 °C 350 A
  • Rated Operational Current DC-3 (Ie):
    (110 V) 2 Poles in Series, 40 °C 350 A
    (220 V) 3 Poles in Series, 40 °C 350 A
  • Rated Operational Current DC-5 (Ie):
    (110 V) 2 Poles in Series, 40 °C 350 A
    (220 V) 3 Poles in Series, 40 °C 350 A
  • Rated Insulation Voltage (Ui):
    acc. to UL/CSA 600 V
    acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
  • Rated Impulse Withstand Voltage (Uimp):
    Main Circuit 8 kV
  • Mechanical Durability:
    5 million
  • Maximum Mechanical Switching Frequency:
    3600 cycles per hour
  • Coil Operating Limits:
    (acc. to IEC 60947-4-1) 0.85 x Uc Min. … 1.1 x Uc Max. (at θ ≤ 70 °C) °C
  • Rated Control Circuit Voltage (Uc):
    60 Hz 230 … 240 V
    50 Hz 220 … 230 V
  • Coil Consumption:
    Pull-in at Max. Rated Control Circuit Voltage 60 Hz 1550 V·A
    Holding at Max. Rated Control Circuit Voltage 50 Hz 60 V·A
    Pull-in at Max. Rated Control Circuit Voltage 50 Hz 1350 V·A
    Holding at Max. Rated Control Circuit Voltage 60 Hz 65 V·A
  • Operate Time:
    Between Coil Energization and NO Contact Closing 17 … 35 ms
    Between Coil De-energization and NO Contact Opening 10 … 16 ms
    Between Coil De-energization and NC Contact Closing 7 … 13 ms
    Between Coil Energization and NC Contact Opening 12 … 30 ms
  • Connecting Capacity Main Circuit:
    Rigid Al-Cable 2×95…120 mm²
    Bar 32 mm
    Rigid Cu-Cable 16…240 mm²
  • Connecting Capacity Auxiliary Circuit:
    Solid 2×1…4 mm²
    Flexible with Insulated Ferrule 1×0.75…2.5 mm²
    Stranded 2×1…4 mm²
    Flexible 1×0.75…2.5 mm²
    Flexible with Ferrule 2×0.75…2.5 mm²
  • Degree of Protection:
    acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
    acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
  • Connecting terminals (delivered in open position) Main poles:
    Flat type c/w screws and bolts
  • Terminal Type:
    Main Circuit: Bars
  • Number of Main Contacts NO:
    3
Brands

ABB